TUCTUCSTORE.ES ≡ Three Piece Nandi-Kamdhenu John Deere Toys Mix And Match Wines In Multiples Of 6 Or Save More With Pre-Selected Bundles!
  • Fluke

  • Fluke 54 II B Data Logging Thermometer with Dual Input

Fluke 54 II B Data Logging Thermometer with Dual Input

$59.3 $106.15
Description Electronic Offset function allows compensation of thermocouple errors to maximize overall accuracy Measures J, K, T, E, R, S, and N-type thermocouples Readout in °C, °F, or Kelvin (K) Splash and dust resistant case protected by impact absorbing holster User-friendly front panel is easy to set up and operate Sleep mode increases battery life; typical 1000-hour battery life Battery door allows easy battery replacement without breaking the calibration seal Optional ToolPak accessory allows the thermometer to hang from any metal object (with the rare earth magnet) or secure around a pipe (with hook-and-loop straps) for hands-free operation 3 year warranty Laboratory accuracy. Wherever you go Fluke 54 II B dual input digital thermometer can log up to 500 points of data to internal memory. Fast response and laboratory accuracy (0.05% 0.3 °C). Take contact temperature for checking motors, insulation, breakers, pipes, corroded connections, liquids, and wires with industrial standard J, K, T, E, N, R, and S type thermocouple (temperature sensors).   General Specifications Temperature accuracy Above -100°C J, K, T, E, and N-type: ±[0.05% 0.3°C]1 R and S-type: ±[0.05% 0.4°C]1 Below -100°C J, K, E, and N-types: ±[0.20% 0.3°C]1 T-type: ±[0.50% 0.3°C] Temperature J-type -210°C to 1200°C K-type -200°C to 1372°C T-type -250°C to 400°C E-type -150°C to 1000°C N-type -200°C to 1300°C1 R and S-type 0°C to 1767°C1 Temperature scale ITS-90 Applicable standards NIST-175 Display resolution 0.1°C, 0.1 K < 1000 1°C, 1 K ≥ 1000 1. Only the Fluke Models 53 II B and 54 II B thermometers are capable of measuring N, R, and S-type thermocouples. Environmental Specifications Operating temperature -10°C to 50°C Storage temperature -40°C to 60°C Humidity (without condensation) 0% to 90%; 0°C to 35°C 0% to 70%; 0°C to 50°C Safety Specifications Overvoltage category CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2 Agency approvals CE, CSA, TÜV (pending) Mechanical and General Specifications Size (L x W x D) 173 x 86 x 38 mm Weight 400 g Batteries 3 AA batteries; typical 1000-hour life
Fluke

Fluke

  • Fluke 80K-40 High Voltage Probe
    $67.92 $118.86
  • Fluke i410 AC/DC Current Clamp
    $60.07 $80.49
  • Fluke 117 Electrician’s Multimeter with Non-Contact Voltage
    $52.94 $85.76
  • Fluke 2AC Non-Contact Voltage Tester
    $60.93 $107.24
  • FLUKE 1577 INSULATION MULTIMETER
    $44.09 $80.24
  • Fluke 27 II Rugged Digital Multimeter
    $58.62 $106.69
  • Fluke 28 II Rugged Digital Multimeter
    $63.9 $121.41
  • Fluke LVD2 Non-Contact Voltage Tester
    $64.57 $93.63
  • FLUKE 1507 INSULATION RESISTANCE TESTER
    $50.12 $71.67
  • Fluke T Pro Electrical Tester
    $37.46 $58.81
  • Fluke 972A/972B/972ES Temperature Humidity Meter
    $40.14 $48.57
  • Fluke 289 True-RMS Data Logging Multimeter
    $36.1 $53.79
  • Fluke 9040 Phase Rotation Indicator
    $42.5 $60.35
  • Fluke 80K-6 High Voltage Probe
    $41.86 $70.32
  • Fluke 1AC II Non-Contact Voltage Tester
    $38.82 $56.29
  • Fluke 287 True-RMS Electronics Logging Multimeter
    $37.05 $49.65

© 2026 - TUCTUCSTORE.ES