Lutron 11 in 1 ANEMOMETER, HUMIDITY/ TEMP. ,Barometer, Altitude, UV ENVIRONMENT METER UV light Model : SP-9202

Shop

Lutron 11 in 1 ANEMOMETER, HUMIDITY/ TEMP. ,Barometer, Altitude, UV ENVIRONMENT METER UV light Model : SP-9202

Sold by: Sirpika Millet
Save 58%
Description * Multi-functions, mini pocket size, 11 in 1 : 1. Air velocity/Temp., 2. Humidity/Temp., 3. Air flow, 4. dew point, 5. Wet bulb, 6. Wind chill, 7. Heat index 8. UV Light , 9. Pt 1000 ohm Temp. ( optional Probe ). 10. Barometer, 11. Altitude.   * Air velocity : 0.4 to 20.0 m/s. * Humidity/Temp. : 10 to 95 %RH. °C/°F. * Air flow : CMM, CFM. * UV Light : 0 to 20.00 mW/cm2, 2 ranges * Barometer : 10.0 to 1100 hPa. * Altitude : -2000 to 9000 m. * LCD with backlight. * Size : 120 mm x 45 mm x 20 mm. * Battery and carrying case are included.   FEATURES * 11 in 1 professional environment instruments: Barometric pressure ( Barometer ) 1. Air velocty/Temp., 2. Humidity/Temp., 3. UV Light 4. Barometer, 5. CFM, CMM, 6. Dew point, Unit Range Resolution Accuracy 7. Wet bulb, 8. Wind chill, 9. Heat index, hPa 10.0 to 999.9 0.1 hpa ± 1.5 hPa 10. Altitude, 11. Pt 1000 ohm Temp.( optional ) 1000 to 1100 1 hpa ± 2 hPa * Tiny bone shape with light weight and small size case mmHg 7.5 to 825.0 0.1 mmHg ± 1.2 mmHg design are suitable for handling with one hand. inHg 0.29 to 32.48 0.01 inHg ± 0.05 inHg * Wristlet design provides extra protection to the instrument especially for user one hand operation. UV Light * auto range * UVA light measurement * Low-friction ball bearing mounted wheel design provides high accuracy at high and low air velocity. Range Resolution Accuracy * UV sensor structure The exclusive UV photo sensor with 0 to 1999 uW/cm^2 1 uW/cm^2 ± ( 4 % FS 2 dgt ) the cosine correction filter. 2 to 20.00 mW/cm^2 0.01 mW/cm^2 FS : full scale * High precision humidity sensor with fast response time. Remark * Build in baro sensor for the atomsphere value * Calibration is executed under the UVA light & and compare with and altitude measurement precisely. the standard UVA light meter. * Optional Pt 1000 ohm Temp. probe for the prcision * UV Sensor structure : Temp. measurement. The exclusive UV photo sensor with the cosine correction filter. * Built- in microprocessor circuit assures excellent * UV sensor spectrum Band pass 290 nm to 390 nm. performance and accuracy. * Concise and compact buttons arrangement, Pt 1000 ohm Thermometer ( optional probe ) easy operation. * Memorize the maximum and minimum value with recall. Unit Range Resolution Accuracy * / detection by pressing ℃ ℉ ng button on the front panel. ℃ -10.0 to 70.0 ℃ 0.1 ℃ ± 1.2 ℃ * Hold function to freeze the current reading value. ℉ 14.0 to 158.0 ℉ 0.1 ℉ ± 2.5 ℉ GENERAL SPECIFICATIONS Ar flow Display 8 mm LCD display Measurement 1. Air velocty/Temp. Unit Range Resolution 2. Humidity/Temp. CMM 0.024 to 36000 0.001/0.01/0.1/1 3. UV Light CFM 0.847 to 1271300 0.001/0.01/0.1/1/10 (x10)/100 (x100) 4. Barometer 5. CFM, CMM 6. Dew point Dew point Temp. 7. Wet bulb 8. Wind chill Unit Range Resolution Remark 9. Heat index ℃ -25.3 to 49.0 ℃ 0.1 ℃ * Calculate from the 10. Altitude ℉ -13.5 to 120.0 ℉ 0.1 ℉ humidity/Temp. value 11. Pt 1000 ohm Temp.( optional ) Please refer to http://en.wikipedia.org/wiki/Dew_point Operating Max. 80% RH. Humidity Wet bulb Temp. Operating 0 to 50 ℃ ( 32 to 122 ℉ ) Temperature Unit Range Resolution Remark Over Input Indication of “- – – – ” ℃ -5.4 to 49.0 ℃ 0.1 ℃ * Calculate from the Display ℉ 22.2 to 120 ℉ 0.1 ℉ humidity/Temp. value Power Supply CR 2032 DC 3V battery Please refer to http://en.wikipedia.org/wiki/Wet-bulb_temperature Power Approx. DC 5 mA Consumption Heat index Weight 160g (battery included) Dimension HWD 120 x 45 x 20 mm (4.7 x 1.8 x 1.2 inch). Unit Range Resolution Accuracy Standard Instruction Manual ℃ 0 to 100.0 ℃ 0.1 ℃ ± 2.0 ℃ Accessory ℉ 32 to 212 ℉ 0.1 ℉ ± 3.6 ℉ Optional Pt 1000 ohm Temp. probe, TP-1000 Pleas refer to http://en.wikipedia.org/wiki/Heat_index Accessories Effects of the heat index (shade values) ELECTRICAL SPECIFICATION ( 23 ± 5℃ ) Celsius Fahrenheit Notes 27– 32 ℃ 80– 90 ℉ Caution : Air velocity Fatigue is possible with prolonged exposure and activity. Continuing activity could result in Unit Range Resolution Accuracy heat cramps ft/min 80 to 3937 ft/min 1 ft/min 32– 41 ℃ 90– 105 ℉ Extreme caution : m/s 0.4 to 20.0 m/s 0.1 m/s ≦ 20 m/s : ± 3% F.S. Heat cramps, and heat exhaustion are possible. km/h 1.4 to 72.0 km/h 0.1 km/h > 20 m/s : ± 4% F.S. Continuing activity could result in heat stroke MPH 0.9 to 44.7 mile/h 0.1 MPH 41– 54 ℃ 105– 130 ℉ Danger : knots 0.8 to 38.8 knots 0.1 knots Heat cramps, and heat exhaustion are likely ; Temp. 0 to 50 ℃ 0.1 ℃ heat stroke is probable with continued activity 32 to 122 ℉ 0.1 ℉ over 54 ℃ over 130 ℉ Extreme danger : Heat stroke is imminent Remark : Note : ft/min : feet per minute MPH : miles per hour Exposure to full sunshine can increase heat index values by up to m/s : meters per second knots : nautical miles per hour 8 ℃ ( 14℉ ). km/h : kilometers per hour Wind chill Humidity/Temp. Unit Range Resolution Accuracy Unit Range Resolution Accuracy ℃ -9.4 to 44.2 ℃ 0.1 ℃ ± 2.0 ℃ % RH 10 to 95 %RH 0.1 %RH < 70% RH : ℉ 15.0 to 112.0 ℉ 0.1 ℉ ± 3.6 ℉ ± 4 %RH * Wind chill value is effect only when the Temp. value < 15 ℃ and ≧70% RH : Air velocity value > 1.4 m/s. ± ( 4 %rdg 1.2 %RH) * Please refer to http://en.wikipedia.org/wiki/Wind_chill Altitude Temp. 0 to 50 ℃ 0.1 ℃ ± 1.2 ℃ Unit Range Resolution Accuracy 32 to 122 ℉ 0.1 ℉ ± 2.5 ℉ m -2000 to 9000 m 1 m ± 15 m ft -6000 to 30000 ft 1 ft ± 50 ft.

Shipping Countries: India


Ready to ship in 1-2 business days


Vendor Information

  • Store Name: Sirpika Millet
  • Vendor: Sirpika Millet
  • Address: No 28, F2 Srinivasa Flat, 6th Street
    Lake View Rd, Madipakkam
    Chennai 600091
    Tamil Nadu
  • No ratings found yet!

Product Enquiry

Your personal data will be used to support your experience throughout this website, to manage access to your account, and for other purposes described in our privacy policy