TUCTUCSTORE.ES ≡ Three Piece Nandi-Kamdhenu John Deere Toys Mix And Match Wines In Multiples Of 6 Or Save More With Pre-Selected Bundles!
  • Fluke

  • Fluke 117 Electrician’s Multimeter with Non-Contact Voltage

Fluke 117 Electrician’s Multimeter with Non-Contact Voltage

$52.94 $85.76
Description The Fluke 117 Electricians Multimeter is a compact, CAT III 600 V, True-rms meter that includes an easy-to-use interface with a bright backlight for darker worksites. It saves you time and enables you to move from job to job more quickly. With a quick turn of the dial you can get measurements for: Resistance Continuity Frequency Capacitance Min/Max/Average For the everyday A digital multimeter designed to be hauled everywhere with you, part of your everyday tools. The 117 is built for demanding applications like: Commercial buildings Hospitals Schools Non-contact voltage detection Keep yourself safer with integrated VoltAlert™ technology. Fast, go/no go non-contact voltage detection built into your multimeter saves you from having to carry around or find an extra tool to get the work started. Automatic AC/DC selection Set the dial and get your measurement quickly with AutoVolt. This automatic AC/DC voltage selector makes it easier for you to get the measurement you need and move on quicker. Frequently asked questions What is the difference between the Fluke 115 and the Fluke 117? While similar, the Fluke 115 and the Fluke 117 meters are designed for slightly different purposes. The Fluke 115 is a compact true-rms digital multimeter that’s great for field service. The Fluke 117 is a designed specifically for electricians. With a quick turn of the dial both units provide measurements for: Resistance Continuity Frequency Capacitance Min/Max/Average The Fluke 117 offers non-contact voltage detection and has a selectable low-impedance mode to prevent false readings from ghost voltage. The 117 also features automatic selection of AC or DC voltage, depending on what was detected. Does the Fluke 117 read milliamps? The Fluke 117 Electrician’s Multimeter includes a 10 amp current range for making both AC or DC current measurements. The maximum resolution is 1 milliamp. Specifications Maximum voltage between any terminal and earth ground 600 V Safety IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293) Display Digital: 6,000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating temperature -10°C to 50°C Storage temperature -40°C to 60°C Battery type 9 volt Alkaline, IEC 6LR61 Battery life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range/resolution 600.0 mV / 0.1 mV Accuracy ±([% of reading] [counts]): 0.5% 2 DC volts Range/resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V Accuracy ±([% of reading] [counts]): 0.5% 2 Auto volts Range/resolution 600.0 V / 0.1 V Accuracy 2.0% 3 (DC, 45 Hz to 500 Hz) 4.0% 3 (500 Hz to 1 kHz) AC millivolts¹ True RMS Range/resolution 600.0 mV / 0.1 mV Accuracy 1.0% 3 (DC, 45 Hz to 500 Hz) 2.0% 3 (500 Hz to 1 kHz) AC volts¹ True RMS Range/resolution 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V Accuracy 1.0% 3 (DC, 45 Hz to 500 Hz) 2.0% 3 (500 Hz to 1 kHz) Continuity Range/resolution 600 Ω / 1 Ω Accuracy Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. Ohms Range/resolution 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ Accuracy 0.9% 1 Range/resolution 40.00 MΩ / 0.01 MΩ Accuracy 5% 2 Diode test Range/resolution 2.00 V / 0.001 V Accuracy 0.9% 2 Capacitance Range/resolution 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF Accuracy 1.9% 2 Range/resolution > 1000 μF Accuracy 5% 20% Lo-Z capacitance Range 1 nF to 500 μF Accuracy 10% 2 typical AC amps True RMS (45 Hz to 500 Hz) Range/resolution 6.000 A / 0.001 A 10.00 A / 0.01 A Accuracy 1.5% 3 20 A continuous overload for 30 seconds max DC amps Range/resolution 6.000 A / 0.001 A   10.00 A / 0.01 A Accuracy 1.0% 3 20 A continuous overload for 30 seconds max Hz (V or A input)² Range/resolution 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 Hz 50.00 kHz / 0.01 Hz Accuracy 0.1% 2 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Fluke

Fluke

  • Fluke 117 Electrician’s Multimeter with Non-Contact Voltage
    $52.94 $85.76
  • Fluke 287 True-RMS Electronics Logging Multimeter
    $37.05 $49.65
  • Fluke i410 AC/DC Current Clamp
    $60.07 $80.49
  • Fluke 1AC II Non-Contact Voltage Tester
    $38.82 $56.29
  • FLUKE 1577 INSULATION MULTIMETER
    $44.09 $80.24
  • FLUKE 1507 INSULATION RESISTANCE TESTER
    $50.12 $71.67
  • Fluke T Pro Electrical Tester
    $37.46 $58.81
  • Fluke 27 II Rugged Digital Multimeter
    $58.62 $106.69
  • Fluke 972A/972B/972ES Temperature Humidity Meter
    $40.14 $48.57
  • Fluke 2AC Non-Contact Voltage Tester
    $60.93 $107.24
  • Fluke 289 True-RMS Data Logging Multimeter
    $36.1 $53.79
  • Fluke 28 II Rugged Digital Multimeter
    $63.9 $121.41
  • Fluke 80K-40 High Voltage Probe
    $67.92 $118.86
  • Fluke 80K-6 High Voltage Probe
    $41.86 $70.32
  • Fluke LVD2 Non-Contact Voltage Tester
    $64.57 $93.63
  • Fluke 9040 Phase Rotation Indicator
    $42.5 $60.35

© 2026 - TUCTUCSTORE.ES