LUTRON O2 METER HUMIDITY/ TEMP, SD CARD DATA RECORDER – O2H-9903SD

Shop

LUTRON O2 METER HUMIDITY/ TEMP, SD CARD DATA RECORDER – O2H-9903SD

Sold by: Sirpika Millet
Save 58%
Description SD Card real time recorder O2 METER Humidity/Temp. Model : O2H-9903SD FEATURES * Real time recorder, save the data into the SD memory Data Output RS 232/USB PC computer interface. card and can be down load to the Excel, extra software * Connect the optional RS232 cable is no need. User can make the further data or graphic UPCB-02 will get the RS232 plug. analysis by themselves. under the Excel software. * Connect the optional USB cable * At the same time, the SD memory card can record 2 USB-01 will get the USB plug. probe’s data ( %RH/Temp. and O2 ) along with the Operating 0 to 50 . ℃ ( 32 to 122 ℉ ). time information into the one Excel file at the same time. Temperature * Manual datalogger is available, during execute the Operating Less than 80% R.H. manual datalogger function, it can set the different Humidity location no. ( position 1 to position 99 ). Weight 350 g/0.77 LB. * Air quality measurement application, multi-function : , Dimension Meter 177 x 68 x 45 mm O2 ( Oxygen in air ), Humidity, temperature Humidity 197 mm in length. measurement. probe * O2 range : 0 to 30.0 % x 0.1 %. O2 probe 150 x 38 x 38 mm * Humidity range: 10 to 95 %RH. Accessories Instruction manual………………………… 1 PC * Dew point Temp. and Wet bulb Temp. measurement. Included Hard carrying case, CA-08………………..1 PC * Temp. range : 0 to 50.0 ℃, ℃/℉. Humidity probe……………………………. 1 PC * O2 sensor : Galvanic cell type. O2 probe……………………………………. 1 PC * Humidity sensor : Precision capacitance sensor Optional * SD memory card ( 2 GB ) * Alarm setting with the beeper sound output. Accessories * AC to DC 9V adapter. * Sampling time for data recorder is 2 seconds to 8 hours. * USB cable, USB-01. * Complete set with 2 probes : * RS232 cable, UPCB-02. O2/Temp. probe, Humidity/Temp. probe, main meter * Data Acquisition software, SW-U801-WIN. and the hard carrying case. * EXCEL Data Acquisition software, SW-E802 * Separate probe, easy for remote measurement. * Meter can cooperate with 2 GB to 16 GB SD card, SD ELECTRICAL SPECIFICATIONS (23± 5 ℃) card is optional. * RS232/USB computer interface. O2 ( Air oxygen ) * Patented. Range 0 to 30 %O2. GENERAL SPECIFICATIONS O2 Resolution 0.1 %O2. Circuit Custom one-chip of microprocessor LSI * Air oxygen Accuracy ± ( 1 % reading 0.2 % O2 ). circuit. @ After calibration Display LCD size : 52 mm x 38 mm Response time ≦ 15 second @ t 90 LCD with green backlight ( ON/OFF ). Overload 100 %O2. Measurement O2 ( Oxygen in air ) protection Humidity Environment 0.9 to 1.1 atmosphere. Dew point Temp., Wet bulb Temp. pressure range Temperature Expected life ≧2 years. Sensor Humidity Precision capacitance sensor time structure O2 Galvanic cell type Alarm If the measurement Air oxygen Temp. Precision thermistor value < 18.0 %O2, the buzzer Datalogger Auto 2 sec to 8 hour 59 min. 59 sec. will sound for warning. Sampling Time @ Sampling time can set to 1 second, Temperature Range 0 ℃ to 50 ℃,32 ℉ to 122 ℉. Setting range but memory data may loss. Resolution 0.1 degree Manual Push the data logger button Accuracy ℃ : ± 0.8 ℃ ℉ : ± 1.5 ℉. once will save data one time. @ Set the sampling time to Humidity/Temperature 0 second. @ Manual mode, can also select the Range 5 % to 95 % R.H. 1 to 99 position ( Location ) no. Humidity Resolution 0.1 % R.H. Data error no. 0.1% of total saved data max. Accuracy ≧70% RH : Memory Card SD memory card. 1 GB to 16 GB. ± (3% reading 1% RH). Advanced * SD memory card Format < 70% RH : setting * Set clock time ± 3% RH. * Set sampling time Range 0 ℃ to 50 ℃,32 ℉ to 122 ℉. @ main setting * Auto power OFF management Temperature Resolution 0.1 degree * Set beep Sound ON/OFF Accuracy ℃ ± 0.8 ℃. * Decimal point of SD card setting ℉ ± 1.5 ℉. * Temp. unit setting * Alarm value setting Dew Point Temp. ( Humidity ) Data Hold Freeze the display reading. Memory Recall Maximum & Minimum value. ℃ Range -25.3 ℃ to 48.9 ℃ Sampling Time Approx. 1 second. Resolution 0.1 ℃ of Display ℉ Range -13.5 ℉ to 120.1 ℉. Power Supply * AAlkaline or heavy duty DC 1.5 V battery Resolution 0.1 ℉. ( UM3, AA ) x 6 PCs, or equivalent. Remark : * ADC 9V adapter input. ( AC/DC power * Dew Point display value is calculated from the adapter is optional ). Humidity/Temp. measurement automatically. Power Current Humidity Normal operation ( w/o SD card save * The Dew Point accuracy is sum accuracy value of Humidity measure- data and LCD Backlight is OFF) : & Temperature measurement.. ment Approx. DC 10.5 mA. When SD card save the data and LCD Wet bulb Temp. ( Humidity ) Backlight is OFF) : Approx. DC 40 mA. ℃ Range -21.6 ℃ to 50.0 ℃ O2 Normal operation ( w/o SD card save Resolution 0.1 ℃ measure- data and LCD Backlight is OFF) : ℉ Range -6.9 ℉ to 122.0 ℉. ment Approx. DC 12.5 mA. Resolution 0.1 ℉. When SD card save the data and LCD Remark : Backlight is OFF) : * Wet bulb display value is calculated from the Humidity/Temp. Approx. DC 42.5 mA. measurement automatically. * AIf LCD backlight on, the power * The Welt bulb accuracy is sum accuracy value of Humidity consumption will increase approx. & Temperature measurement.. 12 mA.

Shipping Countries: India


Ready to ship in 1-2 business days


Vendor Information

  • Store Name: Sirpika Millet
  • Vendor: Sirpika Millet
  • Address: No 28, F2 Srinivasa Flat, 6th Street
    Lake View Rd, Madipakkam
    Chennai 600091
    Tamil Nadu
  • No ratings found yet!

Product Enquiry

Your personal data will be used to support your experience throughout this website, to manage access to your account, and for other purposes described in our privacy policy